I got my gridview and I run the event sorting on header click , like this:
protected void GridViewFoundations_Sorting1(object sender, GridViewSortEventArgs e)
{
DataTable dataTable = GridViewFoundations.DataSource as DataTable;
if (dataTable != null)
{
DataView dataView = new DataView(dataTable);
dataView.Sort = e.SortExpression + " " + ConvertSortDirectionToSql(e.SortDirection);
GridViewFoundations.DataSource = dataView;
GridViewFoundations.DataBind();
}
}
private string ConvertSortDirectionToSql(SortDirection sortDirection)
{
string newSortDirection = String.Empty;
switch (sortDirection)
{
case SortDirection.Ascending:
newSortDirection = "ASC";
break;
case SortDirection.Descending:
newSortDirection = "DESC";
break;
}
return newSortDirection;
}
Now I've two problems :
1) I click on the column header but it only shorts as "ASC" can anyone tell me why ?
2) How can i keep the sorting even when client change pages?
Bind grid function (i have some filters)
protected void BindGridFilters()
{
if (tb_fondeName.Text != "" && tb_fondeId.Text == "")
{
string sqlConnectString = ConfigurationManager.ConnectionStrings["umbracoDbDSN"].ToString();
string sqlSelect = "SELECT cmsDocument.nodeId,text, Max(updateDate) as UpdateDate from cmsContentXml,cmsDocument,cmsContent where cmsContent.nodeId=cmsContentXml.nodeId and cmsDocument.nodeId=cmsContent.nodeId and templateId=3094 and text like '%" + tb_fondeName.Text + "%' group by cmsDocument.nodeId,text";
SqlConnection sqlConnection = new SqlConnection(sqlConnectString);
SqlCommand sqlCommand = new SqlCommand(sqlSelect, sqlConnection);
SqlDataAdapter sqlDa = new SqlDataAdapter(sqlCommand);
DataTable sqlDt = new DataTable();
sqlDa.Fill(sqlDt);
GridViewFoundations.DataSource = sqlDt;
GridViewFoundations.DataBind();
}
if (tb_fondeId.Text != "" && tb_fondeName.Text == "")
{
string sqlConnectString = ConfigurationManager.ConnectionStrings["umbracoDbDSN"].ToString();
string sqlSelect = "SELECT cmsDocument.nodeId,text, Max(updateDate) as UpdateDate from cmsContentXml,cmsDocument,cmsContent where cmsContent.nodeId=cmsContentXml.nodeId and cmsDocument.nodeId=cmsContent.nodeId and templateId=3094 and cmsDocument.nodeId = " + Convert.ToInt32(tb_fondeId.Text) + " group by cmsDocument.nodeId,text";
SqlConnection sqlConnection = new SqlConnection(sqlConnectString);
SqlCommand sqlCommand = new SqlCommand(sqlSelect, sqlConnection);
SqlDataAdapter sqlDa = new SqlDataAdapter(sqlCommand);
DataTable sqlDt = new DataTable();
sqlDa.Fill(sqlDt);
GridViewFoundations.DataSource = sqlDt;
GridViewFoundations.DataBind();
}
if (tb_fondeId.Text != "" && tb_fondeName.Text != "")
{
string sqlConnectString = ConfigurationManager.ConnectionStrings["umbracoDbDSN"].ToString();
string sqlSelect = "SELECT cmsDocument.nodeId,text, Max(updateDate) as UpdateDate from cmsContentXml,cmsDocument,cmsContent where cmsContent.nodeId=cmsContentXml.nodeId and cmsDocument.nodeId=cmsContent.nodeId and templateId=3094 and cmsDocument.nodeId = " + Convert.ToInt32(tb_fondeId.Text) + " and text like '%" + tb_fondeName.Text + "%' group by cmsDocument.nodeId,text";
SqlConnection sqlConnection = new SqlConnection(sqlConnectString);
SqlCommand sqlCommand = new SqlCommand(sqlSelect, sqlConnection);
SqlDataAdapter sqlDa = new SqlDataAdapter(sqlCommand);
DataTable sqlDt = new DataTable();
sqlDa.Fill(sqlDt);
GridViewFoundations.DataSource = sqlDt;
GridViewFoundations.DataBind();
}
if (tb_fondeName.Text == "" && tb_fondeId.Text == "")
{
BindData();
}
}
Create a property GridSortDirection
protected string GridSortDirection
{
get
{
if (ViewState["GridSortDirection"] != null)
{
return Convert.ToString(ViewState["GridSortDirection"]);
}
else
{
return string.Empty;
}
}
set
{
ViewState["GridSortDirection"] = value;
}
}
On page load provide a default sort direction
protected void Page_Load(object sender, EventArgs e)
{
if (!Page.IsPostBack)
{
this.GridSortDirection= "ASC";// setting default value
}
}
now before providing datasource to grid and binding the grid, add following lines and bind like this
SqlDataAdapter sqlDa = new SqlDataAdapter(sqlCommand);
DataTable sqlDt = new DataTable();
sqlDa.Fill(sqlDt);
//added 2 lines
DataView dataView = new DataView(dataTable);
dataView.Sort = e.SortExpression + " " + ConvertSortDirectionToSql(GridSortDirection);
GridViewFoundations.DataSource = dataView;
GridViewFoundations.DataBind();
And now to change sort direction create a function
private string ChangeSortDirection(SortDirection sortDirection)
{
string newSortDirection = String.Empty;
switch (sortDirection)
{
case SortDirection.Ascending:
newSortDirection = "DESC";
break;
case SortDirection.Descending:
newSortDirection = "ASC";
break;
}
return newSortDirection;
}
And call this function in GridViewFoundations_Sorting1 like this
protected void GridViewFoundations_Sorting1(object sender, GridViewSortEventArgs e)
{
DataTable dataTable = GridViewFoundations.DataSource as DataTable;
if (dataTable != null)
{
DataView dataView = new DataView(dataTable);
this.GridSortDirection=ChangeSortDirection(e.SortDirection);
dataView.Sort = e.SortExpression + " " + GridSortDirection;
GridViewFoundations.DataSource = dataView;
GridViewFoundations.DataBind();
}
}
Related
I want to put a combobox in my datagridview. I've tried differents ways (creating a var list<>, creating an arraylist, ect...) and none is working. The thing is my column already exist because of my select query that show my database in the datagridview. But the column is empty since in my database the column is fill with NULL value.
I have two choices : Creating a combobox and do an addcolumn, or if you know how to do it link my combobox to the already existing column. And obviously i need help creating my combobox.
Thank you !
My code :
public partial class Repair : Form
{
public Repair()
{
Main pp = new Main();
InitializeComponent();
this.label4.Text = pp.label3.Text;
SqlConnection maConnexion = new SqlConnection("Server= localhost; Database= Seica_Takaya;Integrated Security = SSPI; ");
maConnexion.Open();
SqlCommand command = maConnexion.CreateCommand();
SqlCommand command1 = maConnexion.CreateCommand();
if (Program.UserType == "admin")
{
command.CommandText = "SELECT Message, FComponent, ReadValue, ValueReference, RepairingTime FROM FailAndPass WHERE FComponent IS NOT NULL";
command1.CommandText = "SELECT Machine, BoardName, BoardNumber FROM FailAndPass WHERE FComponent IS NOT NULL";
}
else
{
command.CommandText = "SELECT Message, FComponent, ReadValue, ValueReference, RepairingTime FROM FailAndPass WHERE ReportingOperator IS NULL AND FComponent IS NOT NULL";
command1.CommandText = "SELECT Machine, BoardName, BoardNumber FROM FailAndPass WHERE ReportingOperator IS NULL AND FComponent IS NOT NULL";
}
SqlDataAdapter sda = new SqlDataAdapter(command);
SqlDataAdapter sda1 = new SqlDataAdapter(command1);
DataTable dt = new DataTable();
DataTable dt1 = new DataTable();
sda.Fill(dt);
sda1.Fill(dt1);
DataColumn dcIsDirty = new DataColumn("IsDirty", typeof(bool));
DataColumn dcIsDirty1 = new DataColumn("IsDirty", typeof(bool));
dcIsDirty.DefaultValue = false;
dcIsDirty1.DefaultValue = false;
dataGridView1.DataSource = dt;
dataGridView2.DataSource = dt1;
DataGridViewComboBoxColumn combo = new DataGridViewComboBoxColumn();
combo.HeaderText = "FaultCodeByOp";
combo.Name = "combo";
ArrayList list = new ArrayList();
list.Add("C-C");
list.Add("C-O");
combo.Items.AddRange(list.ToArray());
dataGridView1.Columns.Add(combo);
dt.Columns.Add(dcIsDirty);
dt1.Columns.Add(dcIsDirty1);
maConnexion.Close();
dataGridView1.Columns[6].Visible = false;
dataGridView2.Columns[3].Visible = false;
foreach (DataGridViewRow row in dataGridView1.Rows)
{
for(int i=0;i<4;i++)
{
dataGridView1.Columns[i].ReadOnly = true;
}
}
foreach (DataGridViewRow row in dataGridView2.Rows)
{
for(int i=0;i<3;i++)
{
dataGridView2.Columns[i].ReadOnly = true;
}
}
}
private void button2_Click(object sender, EventArgs e)
{
this.Hide();
Main ff = new Main();
ff.Show();
}
private void textBox1_TextChanged(object sender, EventArgs e)
{
SqlConnection maConnexion = new SqlConnection("Server= localhost; Database= Seica_Takaya;Integrated Security = SSPI; ");
maConnexion.Open();
string Var1 = textBox1.Text;
SqlCommand command = maConnexion.CreateCommand();
SqlCommand command1 = maConnexion.CreateCommand();
if (Program.UserType == "admin")
{
if (textBox1.Text != String.Empty)
{
//command.Parameters.AddWithValue("#BoardName", Var1 + "%");
//command.Parameters.AddWithValue("#Machine", Var1 + "%");
command.Parameters.AddWithValue("#SerialNum", Var1 + "%");
command1.Parameters.AddWithValue("#SerialNum", Var1 + "%");
//command.Parameters.AddWithValue("#FComponent", Var1 + "%");
//command.CommandText = "SELECT * FROM FailAndPass WHERE BoardName LIKE #BoardName OR Machine LIKE #Machine OR SerialNum LIKE #SerialNum OR FComponent LIKE #FComponent";
command.CommandText = "SELECT Message, FComponent, ReadValue, ValueReference, FaultCodeByOp, RepairingTime FROM FailAndPass WHERE SerialNum LIKE #SerialNum AND FComponent IS NOT NULL";
command1.CommandText = "SELECT Machine, BoardName, BoardNumber FROM FailAndPass WHERE SerialNum LIKE #SerialNum And FComponent IS NOT NULL";
}
}
else
{
if (textBox1.Text != String.Empty)
{
//command.Parameters.AddWithValue("#BoardName", Var1 + "%");
//command.Parameters.AddWithValue("#Machine", Var1 + "%");
command.Parameters.AddWithValue("#SerialNum", Var1 + "%");
command1.Parameters.AddWithValue("#SerialNum", Var1 + "%");
//command.Parameters.AddWithValue("#FComponent", Var1 + "%");
//command.CommandText = "SELECT * FROM FailOnly WHERE (BoardName LIKE #BoardName OR Machine LIKE #Machine OR SerialNum LIKE #SerialNum OR FComponent LIKE #FComponent) AND ReportingOperator IS NULL ";
command.CommandText = "SELECT Message, FComponent, ReadValue, ValueReference, FaultCodeByOp, RepairingTime FROM FailAndPass WHERE (SerialNum LIKE #SerialNum) AND ReportingOperator IS NULL AND FComponent IS NOT NULL ";
command1.CommandText = "SELECT DISTINCT Machine, BoardName, BoardNumber FROM FailAndPass WHERE (SerialNum LIKE #SerialNum) AND ReportingOperator IS NULL AND FComponent IS NOT NULL";
}
}
if (!string.IsNullOrWhiteSpace(textBox1.Text))
{
SqlDataAdapter sda = new SqlDataAdapter(command);
SqlDataAdapter sda1 = new SqlDataAdapter(command1);
DataTable dt = new DataTable();
DataTable dt1 = new DataTable();
sda.Fill(dt);
sda1.Fill(dt1);
DataColumn dcIsDirty = new DataColumn("IsDirty", typeof(bool));
DataColumn dcIsDirty1 = new DataColumn("IsDirty", typeof(bool));
dcIsDirty.DefaultValue = false;
dcIsDirty1.DefaultValue = false;
dt.Columns.Add(dcIsDirty);
dt1.Columns.Add(dcIsDirty1);
dataGridView1.DataSource = dt;
dataGridView2.DataSource = dt1;
maConnexion.Close();
dataGridView1.Columns[6].Visible = false;
dataGridView2.Columns[3].Visible = false;
}
}
private void button1_Click(object sender, EventArgs e)
{
SqlConnection maConnexion = new SqlConnection("Server= localhost; Database= Seica_Takaya;Integrated Security = SSPI; ");
maConnexion.Open();
foreach (DataGridViewRow row in dataGridView1.Rows)
{
if ((row.Cells[6].Value != null) && (bool)row.Cells[6].Value)
{
SqlCommand command = maConnexion.CreateCommand();
command = new SqlCommand("update FailAndPass set FaultCodeByOp=#Fault, RepairingDate=#RD, RepairingTime = #RT, ReportingOperator=#RO WHERE SerialNum=#Serial", maConnexion);
command.Parameters.AddWithValue("#Fault", row.Cells[4].Value != null ? row.Cells[4].Value : DBNull.Value);
command.Parameters.AddWithValue("#RD", DateTime.Today.ToString("d"));
command.Parameters.AddWithValue("#RT", row.Cells[5].Value != null ? row.Cells[5].Value : DBNull.Value);
command.Parameters.AddWithValue("#RO", this.label4.Text);
command.Parameters.AddWithValue("#Serial", this.textBox1.Text);
command.ExecuteNonQuery();
}
}
maConnexion.Close();
this.Hide();
Repair rep = new Repair();
rep.Show();
}
private void dataGridView1_CellEndEdit(object sender, DataGridViewCellEventArgs e)
{
if (dataGridView1.IsCurrentRowDirty)
{
dataGridView1.Rows[e.RowIndex].Cells[6].Value = true;
}
}
}
private void ComboboxInDatagridview()
{
var dataGridView1 = new DataGridView();
DataGridViewComboBoxColumn combo = new DataGridViewComboBoxColumn();
combo.HeaderText = "FaultCodeByOp";
combo.Name = "combo";
dataGridView1.Columns.AddRange(new DataGridViewColumn[] { combo });
ArrayList list = new ArrayList() { "C-C", "C-O" };
var rowindex = dataGridView1.Rows.Add();
DataGridViewComboBoxCell cmbCell = (DataGridViewComboBoxCell)dataGridView1["combo", rowindex];
//Or
//var columnindex = 0;
//DataGridViewComboBoxCell cmbCell = (DataGridViewComboBoxCell)dataGridView1[columnindex, rowindex];
cmbCell.DataSource = list;
}
Anyone having other solutions ? I've tried something else :
DataGridViewComboBoxColumn combo = new DataGridViewComboBoxColumn();
ArrayList list1 = new ArrayList(); //{ "C-C", "C-O", "Absence composant", "Mauvaise valeur", "Mauvais sens", "Mauvais composant" };
list1.Add("C-C");
list1.Add("C-O");
combo.DataSource = list1;
combo.HeaderText = "FaultCodeByOp";
combo.DataPropertyName = "FaultCodeByOp";
dataGridView1.Columns.AddRange(combo);
didnt change anything.
I dont know what i've done, but it is not greyish anymore. Now it is white like other columns.... but it doesnt dropdown, nor show members of the list.
Below is my code C# net4 for sorting column in GridView but I've this error:
CS1502: The best overloaded method match for System.Data.DataView.DataView(System.Data.DataTable) has some invalid arguments
in this line why?: DataView sortedView = new DataView(GridViewBind());
public SortDirection dir
{
get
{
if (ViewState["dirState"] == null)
{
ViewState["dirState"] = SortDirection.Ascending;
}
return (SortDirection)ViewState["dirState"];
}
set
{
ViewState["dirState"] = value;
}
}
protected void gridView_Sorting(object sender, GridViewSortEventArgs e)
{
string sortingDirection = string.Empty;
if (dir == SortDirection.Ascending)
{
dir = SortDirection.Descending;
sortingDirection = "Desc";
}
else
{
dir = SortDirection.Ascending;
sortingDirection = "Asc";
}
DataView sortedView = new DataView(GridViewBind());
sortedView.Sort = e.SortExpression + " " + sortingDirection;
GridView1.DataSource = sortedView;
GridView1.DataBind();
}
public void GridViewBind()
{
sql1 = " SELECT * FROM `tbl` ORDER BY empid DESC; ";
dadapter = new OdbcDataAdapter(sql1, myConnectionString);
dset = new DataSet();
dset.Clear();
dadapter.Fill(dset);
GridView1.DataSource = dset.Tables[0];
GridView1.DataBind();
dadapter.Dispose();
dadapter = null;
myConnectionString.Close();
}
The error is due to this line
DataView sortedView = new DataView(GridViewBind());
The function GridViewBind() return type is void which is incorrect. It should return a DataTable.
If it returns DataTable then your code will work.
You need to modify your function as follow
public DataTable GridViewBind()
{
sql1 = " SELECT * FROM `tbl` ORDER BY empid DESC; ";
dadapter = new OdbcDataAdapter(sql1, myConnectionString);
dset = new DataSet();
dset.Clear();
dadapter.Fill(dset);
DataTable dt=dset.Tables[0];
GridView1.DataSource = dt;
GridView1.DataBind();
dadapter.Dispose();
dadapter = null;
myConnectionString.Close();
return dt;
}
Use DataView to sot the data.
public void GridViewBind()
{
sql1 = " SELECT * FROM `tbl` ORDER BY empid DESC; ";
dadapter = new OdbcDataAdapter(sql1, myConnectionString);
dset = new DataSet();
dset.Clear();
dadapter.Fill(dset);
DataTable dt = new DataTable();
dt=dset.Tables[0];
DataView dv = dt.DefaultView;
dv.Sort = "empid desc";
DataTable sortedDT = dv.ToTable();
GridView1.DataSource = sortedDT;
GridView1.DataBind();
dadapter.Dispose();
dadapter = null;
myConnectionString.Close();
}
I am having problem in sorting the searched records in a gridview to ascending and descending directions. I have applied the following code to normal gridview (all records) and it is working all fine but when I try to search any records from all records, and try to sort those searched records, following code neither performs any actions nor throws any errors: Following code is applied for sorting:
protected void GridView2_Sorting(object sender, GridViewSortEventArgs e)
{
string sortExpression = e.SortExpression;
if (GridViewSortDirection == SortDirection.Ascending)
{
GridViewSortDirection = SortDirection.Descending;
SortGridView1(sortExpression, DESCENDING);
}
else
{
GridViewSortDirection = SortDirection.Ascending;
SortGridView1(sortExpression, ASCENDING);
}
}
private void SortGridView1(string sortExpression, string direction)
{
DataTable dt = SearchTable().Tables[0];
DataView dv = new DataView(dt);
dv.Sort = sortExpression + direction;
GridView2.DataSource = dv;
GridView2.DataBind();
}
Search function code is:
public DataSet SearchTable()
{
string sql1 = "SELECT * from dbo.Documents1";
bool flag = false;
if (!txtRef.Text.Equals(""))
{
if (flag == false)
{
sql1 = sql1 + " where Ref LIKE N'%" + txtRef.Text + "%'";
flag = true;
}
else
{
sql1 = sql1 + " and Ref LIKE N'%" + txtRef.Text + "%'";
}
}
if (!txtSubject.Text.Equals(""))
{
if (flag == false)
{
sql1 = sql1 + " where Subject LIKE N'%" + txtSubject.Text + "%'";
flag = true;
}
else
{
sql1 = sql1 + " and Subject LIKE N'%" + txtSubject.Text + "%'";
}
}
}
using (SqlConnection con = new SqlConnection("Data Source=MEHDI-PC\\SQLEXPRESS;Initial Catalog=PIMS;Integrated Security=True"))
{
using (SqlCommand cmd = new SqlCommand())
{
cmd.Connection = con;
cmd.CommandText = sql1 + ";";
//cmd.CommandType = CommandType.StoredProcedure;
con.Open();
//dataset object to get all select statement results
DataSet ds = new DataSet();
//sql dataadoptor to fill dataset
using (SqlDataAdapter adp = new SqlDataAdapter(cmd))
{
adp.Fill(ds);
}
if (con.State == ConnectionState.Open)
{
con.Close();
}
return ds;
}
}
}
PageLoad Event function is:
protected void Page_Load(object sender, EventArgs e)
{
GridView1.DataSource = rpt.Documents1s.ToList();
GridView1.DataBind();
if (!IsPostBack)
{
BindGrid();
MultiView1.SetActiveView(vHome);
btnBacktoHome.Visible = false;
lblStatus.Visible = false;
}
}
I cant understand where I am going wrong. when clicked on a column to sort, it took me out of searched records and sorted "All-Records" which are placed in GridView1 while searched-records are placed in GridView2 as shown in the code. what I am failed to understand is, why programs jumps to GridView1 and sort all-records there when I click to click to sort searched-records in GridView2. Any help will be much appreciated. Thanks in advance.
Did you use the gridview binding code in inside of !ISPostBack ? like
protected void Page_Load(object sender, EventArgs e)
{
if(!IsPostBack)
{
//Grid Binding code
}
}
Edit for you page load code(Must add the databind in inside of !IsPostBack)
protected void Page_Load(object sender, EventArgs e)
{
if (!IsPostBack)
{
GridView1.DataSource = rpt.Documents1s.ToList();
GridView1.DataBind();
BindGrid();
MultiView1.SetActiveView(vHome);
btnBacktoHome.Visible = false;
lblStatus.Visible = false;
}
}
I am using window.open to open 2 different pages in pop-up windows,but for some reason both the triggers opens the same page in the pop-up window,heres how I am trying to do this:
first:
Response.Write("<script type='text/javascript'>window.open('TransEditEntry.aspx','mywindow','width=850px,height=300px,left=0,top=10,screenX=100,screenY=10')</script>");
second:
Response.Write(#"<script type='text/javascript'>window.open('TransNewEntry.aspx','','width=850px,height=300px,left=0,top=10,screenX=100,screenY=10')</script>");
this opens 'TransEditEntry.aspx' page instead of 'TransNewEntry.aspx'`
here the rest of the code:
The entire function which is called on add button click:
protected void addNew(object sender, EventArgs e)
{
//HiddenField sr = (HiddenField)GridView1.SelectedRow.Cells[6].FindControl("srno");
//Session["TransSrNo"] = sr.Value;
Response.Write(#"<script type='text/javascript'>window.open('TransNewEntry.aspx','','width=850px,height=300px,left=0,top=10,screenX=100,screenY=10')</script>");
//Session["transAdd"] = "1";
}
The add button which calls the function:
<asp:Button ID="AddBtn" runat="server" OnClick="addNew" Text="Add"/>
The page TransNewEntry.aspx.cs
public partial class TransEditEntry : System.Web.UI.Page
{
SqlConnection con = new SqlConnection(GetConnectionString.Get());
string subCode;
DataTable dt;
SqlDataAdapter sda;
SqlCommandBuilder build;
DataRow dr;
DataSet ds = new DataSet();
protected void Page_Load(object sender, EventArgs e)
{
Response.Write((Session["TransSrNo"]).ToString());
int SRno = Convert.ToInt32((Session["TransSrNo"]).ToString());
con.Open();
SqlCommand cmd3 = new SqlCommand("select sub_code from tran_dtls where sr_no='" + SRno + "'", con);
subCode = (string)cmd3.ExecuteScalar();
con.Close();
if (!IsPostBack)
{
sda = new SqlDataAdapter("select * from tran_dtls where sr_no=" + SRno + "", con);
build = new SqlCommandBuilder(sda);
dt = new DataTable();
sda.Fill(dt);
foreach (DataRow row in dt.Rows)
{
srNoTxt.Text = "";
amttxt.Text = "";
partTxt.Text = "";
checkNoTxt.Text = "";
checkDtTxt.Text = "";
refNoTxt.Text = "";
refDtTxt.Text = "";
jobNoTxt.Text = "";
}
}
}
protected void GlChange(object sender, EventArgs e)
{
con.Open();
SqlCommand cmd4 = new SqlCommand("select ac_type from ac_mstr where AC_desc='" + GlDrp.SelectedValue + "'", con);
string acType = (string)cmd4.ExecuteScalar();
SqlCommand cmd5 = new SqlCommand("select gl_code from ac_mstr where AC_desc='" + GlDrp.SelectedValue + "'", con);
string gl_code = (string)cmd5.ExecuteScalar();
if (acType == "S")
{
SqlDataSource3.SelectCommand = ("select ac_desc from ac_mstr where gl_code='" + gl_code + "'");
subDrp.DataBind();
subDrp.Enabled = true;
//Response.Write("<script type='javacript/text'>alert('1')</script>");
}
else
{
subDrp.Enabled = false;
//Response.Write("<script type='javacript/text'>alert('2')</script>");
}
con.Close();
}
protected void saveRow(object sender, EventArgs e)
{
int SRno = Convert.ToInt32((Session["TransSrNo"]).ToString());
sda = new SqlDataAdapter("select * from tran_dtls where tc='" + Session["TC"] + "' and doc_no='" + Session["docNo"] + "' ", con);
build = new SqlCommandBuilder(sda);
//dt = new DataTable();
// DataSet ds = new DataSet();
sda.Fill(ds);
dt = (DataTable)ViewState["myViewState"];
if (Session["gridRow"] == null)
{
dt = ds.Tables[0];
dr = dt.NewRow();
dr["GL_code"] = GlDrp.SelectedValue;
dr["sub_code"] = subDrp.SelectedValue;
dr["particulars"] = partTxt.Text;
dr["chq_no"] = checkNoTxt.Text;
dr["chq_dt"] = checkDtTxt.Text;
dr["ref_no"] = refNoTxt.Text;
dr["ref_dt"] = refDtTxt.Text;
dr["dbcr"] = dbcrDrp.SelectedValue.ToString().Substring(0, 1);
dr["amt"] = amttxt.Text;
dr["job_no"] = jobNoTxt.Text;
dr["EMP"] = empDrop.SelectedValue;
dt.Rows.Add(dr);
dt.AcceptChanges();
ViewState["myViewState"] = dt;
//Session["gridRow"] = dt;
Session["gridRow"] = dt;
Session["saveToggle"] = "1";
closeFunction();
Response.Write("<script type='text/javascript'>this.close()</script>");
}
else
{
dt = (DataTable)Session["gridRow"];
dr = dt.NewRow();
dr["GL_code"] = GlDrp.SelectedValue;
dr["sub_code"] = subDrp.SelectedValue;
dr["particulars"] = partTxt.Text;
dr["chq_no"] = checkNoTxt.Text;
dr["chq_dt"] = checkDtTxt.Text;
dr["ref_no"] = refNoTxt.Text;
dr["ref_dt"] = refDtTxt.Text;
dr["dbcr"] = dbcrDrp.SelectedValue.ToString().Substring(0, 1);
dr["amt"] = amttxt.Text;
dr["job_no"] = jobNoTxt.Text;
dr["EMP"] = empDrop.SelectedValue;
dt.Rows.Add(dr);
dt.AcceptChanges();
ViewState["myViewState"] = dt;
//Session["gridRow"] = dt;
Session["gridRow"] = dt;
Session["saveToggle"] = "1";
//Response.Write("<script type='text/javascript'>window.opener.location.reload(true);</script>");
closeFunction();
Response.Write("<script type='text/javascript'>this.close()</script>");
}
}
private void closeFunction()
{
StringBuilder sb = new StringBuilder();
sb.Append("window.opener.RefreshPage();");
sb.Append("window.close();");
ClientScript.RegisterClientScriptBlock(this.GetType(), "CloseWindowScript", sb.ToString(), true);
}
}
Check your condition where you are doing : Response.Write. Both the conditions must be pointing out for first>
I am trying to implement sorting functionality in grid view but its not working..
Code:
//enter code here
public partial class _Default : System.Web.UI.Page
{
SqlConnection con;
SqlCommand cmd;
DataSet ds;
SqlDataAdapter da;
protected void Page_Load(object sender, EventArgs e)
{
if (!IsPostBack)
{
Session["myDataSet"] = FillDataSet();
}
}
private string ConvertSortDirectionToSql(SortDirection sortDirection)
{
string newSortDirection = String.Empty;
switch (sortDirection)
{
case SortDirection.Ascending:
newSortDirection = "ASC";
break;
case SortDirection.Descending:
newSortDirection = "DESC";
break;
}
return newSortDirection;
}
protected DataSet FillDataSet()
{
string source = "Database=GridTest;Server=Localhost;Trusted_Connection=yes";
con = new SqlConnection(source);
cmd = new SqlCommand("proc_mygrid", con);
ds = new DataSet();
da = new SqlDataAdapter(cmd);
da.Fill(ds);
GridView1.DataSource = ds;
GridView1.DataBind();
return ds;
}
protected void GridView1_Sorting(object sender, GridViewSortEventArgs e)
{
//DataSet ds = FillDataSet();
DataTable dt = ((DataSet)Session["myDataSet"]).Tables[0];
if (dt != null)
{
dt.DefaultView.Sort = e.SortExpression + " " + ConvertSortDirectionToSql(e.SortDirection);
GridView1.DataSource = dt;
GridView1.DataBind();
}
Can somebody suggest where I am going wrong?
EDIT:
enter code here DataTable dtbl = ((DataSet)Session["myDataSet"]).Tables[0];
dtbl.DefaultView.Sort = e.SortExpression + " " + ConvertSortDirectionToSql(e.SortDirection);
GridView1.DataSource = dtbl;
GridView1.DataBind();
Here is the running code:
private string GetSortDirection(string column)
{
string sortDirection = "DESC";
string sortExpression = ViewState["SortExpression"] as string;
if (sortExpression != null)
{
if (sortExpression == column)
{
string lastDirection = ViewState["SortDirection"] as string;
if ((lastDirection != null) && (lastDirection == "DESC"))
{
sortDirection = "ASC";
}
}
}
ViewState["SortDirection"] = sortDirection;
ViewState["SortExpression"] = column;
return sortDirection;
}
protected void GridView1_Sorting(object sender, GridViewSortEventArgs e)
{
DataTable dtbl = ((DataSet)Session["myDataSet"]).Tables[0];
dtbl.DefaultView.Sort = e.SortExpression + " " + GetSortDirection(e.SortExpression);
GridView1.DataSource = dtbl;
GridView1.DataBind();
}